电子束辐照冷却猪肉杀菌工艺优化
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

河南省杰出人才创新基金项目(0521000600);郑州轻工业学院博士科研启动基金项目(2005BSJJ14)


Process optimization of electron beam radiation on chilled pork
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    该研究采用响应曲面法,以辐照剂量和束流能量为变量,以菌落总数、红度值和亮度值为试验指标,优化电子束辐照对冷却肉(肉块的长度约为14~15 cm,宽度约为7~8 cm,厚度约为2~2.5 cm)既达到杀菌保鲜效果又最大限度不影响色泽的最佳参数范围。结果表明,在辐照剂量为3.09~3.63 kGy,束流能量为2.37~3.51 MeV的参数范围内,冷却肉菌落总数下降2个对数单位;束流能量与辐照剂量之间存在协同增效作用,但束流能量在杀菌过程中发挥的作用是最主要的。辐照剂量为2.38 kGy,束流能量为2.64 MeV时,红度值最小,在辐照剂量2.24~2.99 kGy,束流能量2.28~2.91 MeV的参数范围,肉色保持鲜红,与对照接近。辐照剂量为2.67 kGy,束流能量为2.55 MeV时,亮度值有最大值且与对照值接近;在辐照剂量为2.05~2.92 kGy,束流能量为2.09~2.80 MeV参数范围,肉的色泽保持鲜艳。电子束辐照对冷却肉既达到杀菌保鲜效果又不显著影响色泽的最优参数为:束流能量为2.80 MeV,辐照剂量为3.09 kGy。研究结果能够为电子束辐照技术应用于肉类工业和在线辐照设备的研制提供技术支持。

    Abstract:

    Effects of electron beam radiation on sterilization and color of chilled pork(14-15 cm in length, 7-8 cm in breadth, 2-2.5 cm in height)were studied by using response surface analysis through taking electron beam energy and dose as factors, colony form unit, value of redness, and value of lightness as responses. The results were as follows: There was an interaction between electron beam energy and dose, but electron beam energy played a leading role in sterilization. When dose ranged from 3.09 to 3.63 kGy and electron beam energy ranged from 2.37 to 3.51 MeV, the colony form unit would drop 2 logarithm units. The value of redness was minimum value when dose was 2.38 kGy and electron beam energy was 2.64 MeV. The value of redness was close to the control when the dose ranged from 2.24 to 2.99 kGy and the electron beam energy ranged from 2.28 to 2.91 MeV. The value of lightness was maximum and closed to the control as dose was 2.67 kGy and electron beam energy was 2.55 MeV. The value of lightness would become more acceptable when the dose ranged from 2.05 to 2.92 kGy and electron beam energy ranged from 2.09 to 2.8 MeV. The results showed that the optimal parameters of electron beam radiation on chilled pork were 2.8 MeV and 3.09 kGy. This study would provide the technical basis for application of electron beam radiation on pork industry.

    参考文献
    相似文献
    引证文献
引用本文

白艳红,赵电波,毛多斌,贾春晓,钱学梅,杨公明.电子束辐照冷却猪肉杀菌工艺优化[J].农业工程学报,2009,25(12):312-317.

Bai Yanhong, Zhao Dianbo, Mao Duobin, Jia Chunxiao, Qian Xuemei, Yang Gongming. Process optimization of electron beam radiation on chilled pork[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE),2009,25(12):312-317.

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2008-04-22
  • 最后修改日期:2009-08-26
  • 录用日期:
  • 在线发布日期:
  • 出版日期:
文章二维码
您是第位访问者
ICP:京ICP备06025802号-3
农业工程学报 ® 2024 版权所有
技术支持:北京勤云科技发展有限公司