    摘要:

    实现土壤电导率的快速获取可为农业生产精准管理提供有效的数据支撑。目前,田间电导率采集在农业生产前进行,需要专门的电导率检测设备对种植田块开展大范围数据采集并生成电导率空间分布图,该方式操作繁琐、费时费力,同时检测的电导率值由于时间滞后原因,难以准确反映农业生产各环节(如播种)实施过程中的真实电导率情况。针对上述问题,基于交流“电流-电压”四端法原理,该研究设计了一种土壤电导率原位快速检测传感器,用于搭载在不同的农业生产机具上,实现土壤电导率的实时检测与作业参数的在线调整。该传感器以STM32处理器为核心,配合电源电路、交流信号源电路、有效值检测电路及其他外围电路搭建了硬件及软件架构,同时集成了信息的实时检测与显示、定时存储与无线传输等功能,实现了土壤电导率的原位高精度获取。传感器标定试验及工作稳定性试验结果表明,传感器输出值与DDB-303A电导率仪测得的电导率值呈明显线性关系,线性拟合R2为0.995,且在不同电导率水平下,连续测量的标准偏差均小于0.76 μS/cm,具有较高的准确性及工作稳定性。与JXBS-3001传感器在实验室条件下(温度25 ℃),对配置的不同电导率浓度土样(含水率<15%)检测的对比试验结果表明,所设计的电导率传感器的测量误差及响应时间更低,绝对误差为-5.9~19.4 μS/cm,相对误差为-1.05%~2.39%,响应时间小于2.01 s。利用电导率传感器在现场(温度20.6 ℃)对地块不同位置测量的绝对误差为-11.36~25.30 μS/cm,相对误差为-7.91%~7.88%。综合而言,该研究所设计的土壤电导率传感器能快速准确的检测土壤电导率信息,可为无人农场的土壤信息采集提供一种高精度的检测工具。

    Abstract:

    Soil electrical conductivity is an important parameter that characterizes soil quality and physical properties. The rapid acquisition of soil electrical conductivity can provide effective data support for accurate management of agricultural products such as variable-rate fertilization, variable-rate seeding, and other soil improvement operations. At present, the collection of field electrical conductivity is carried out before agricultural production, and special electrical conductivity detection equipment is needed to carry out large-scale data collection and generate a spatial distribution map of electrical conductivity for planting plots. The operation of this method is cumbersome, time-consuming, and laborious., and the detected electrical conductivity value is difficult to accurately reflect the real conductivity in each link of agricultural production (such as sowing) due to at the time lag. Aiming at the above problems, a rapid in-situ detection sensor for soil electrical conductivity was designed based on the principle of the AC "current-voltage" four-electrode method. It is used to carry on different agricultural production machines to realize the real-time detection of soil electrical conductivity and online adjustment of operating parameters. The STM32 processor was taken as the core component of the sensor, cooperating with the power supply circuit, AC signal source circuit, effective value detection circuit, and other peripheral circuits to build a hardware and software architecture, to realize the high-precision in-situ and rapid acquisition of soil conductivity. The four probes of the sensor are in direct contact with the soil, all of which are made of stainless steel solid material with a length of 65 mm and a diameter of 3 mm. The probes are fixed on the PVC fixing plate with a pitch of 20 mm between them through the nut. The sensor probe and the main shell are connected by the shield wires to avoid the cross-interference of signals. The fixing plate can be separated from the main shell to adapt to different working environment requirements. The STM32 processor controls the AD9833 signal generation module of the AC signal source module through SPI to output a sine wave signal with adjustable frequency and amplitude. It obtains data through the communication between IIC and the RMS detection module, and processes, displays, stores and transmits the data. The LCD1602 liquid crystal display module adopts four-wire communication to display the output value of the electrical conductivity sensor in real-time. An integrated SD card storage module is used for real-time storage of data. WiFi wireless module is integrated with ESP8266 as the core component to realize wireless data transmission. The reserved interface can also be equipped with GPS equipment for location information acquisition, which is convenient for later function expansion. The designed power supply circuit adopts an independent power supply for each functional module and main chip to eliminate signal interference and improve detection accuracy. The designed electrical conductivity sensor has been calibrated and tested for working stability. The calibration test results show that the electrical conductivity values output by the electrical conductivity sensor are significantly linear with that measured by the DDB-303A conductivity instrument, and the linear fitting correlation is 0.995. The experimental results show that the standard deviation of the measured value is less than 0.76 μS/cm under different soil electrical conductivity levels. Soil samples with different conductivity concentrations (moisture content<15%) were prepared under laboratory conditions (temperature 25 ℃). The contrast test of soil conductivity detection accuracy and response time was carried out by using the designed conductivity sensor and JXBS-3001 sensor. The test results show that with the increase of soil conductivity, the measurement errors of the JXBS -3001 sensor and designed conductivity sensor also increases. Among them, the absolute error of the JXBS-3001 sensor is ?13.8-30.3 μS/cm, the relative error is ?2.46%-3.74%. And the absolute error of the designed electrical conductivity sensor is ?5.9-19.4 μS/cm, the relative error is ?1.05%-2.39%, indicating that the designed conductivity sensor has a smaller measurement error than the JXBS-3001 sensor at a lower production cost, and the measurement accuracy is reliable. The response time comparison test results show that the response time of the JXBS-3001 sensor in the two states is 2.23 s, and the response time of the designed electrical conductivity sensor is less than 2.01 s. Conductivity sensors were used to measure the conductivity at different locations of the field at a temperature of 20.6 ℃, and the results were compared with those obtained in the laboratory. The results show that the absolute error is ?11.36-25.30 μs /cm, and the relative error is ?7.91%-7.88%. The designed sensor can switch between different working states more quickly, and realize the rapid and effective acquisition of the information of the soil electrical conductivity. In summary, the designed soil electrical conductivity sensor can rapidly and accurately detect soil electrical conductivity, which can provide a high-precision detection tool for soil information collection in unmanned farms.

    参考文献
    相似文献
    引证文献
引用本文

钟翔君,杨丽,张东兴,崔涛,和贤桃,杜兆辉.四端法土壤电导率原位快速检测传感器设计与试验[J].农业工程学报,2021,37(9):90-99. DOI:10.11975/j. issn.1002-6819.2021.09.011

Zhong Xiangjun, Yang Li, Zhang Dongxing, Cui Tao, He Xiantao, Du Zhaohui. Design and experiment of a sensor for in-situ rapid detection of soil electrical conductivity using four-electrode method[J]. Transactions of the Chinese Society of Agricultural Engineering (Transactions of the CSAE),2021,37(9):90-99. DOI:10.11975/j. issn.1002-6819.2021.09.011

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-03-16
  • 最后修改日期:2021-05-01
  • 录用日期:
  • 在线发布日期: 2021-05-28
  • 出版日期:
文章二维码
您是第位访问者
ICP:京ICP备06025802号-3
农业工程学报 ® 2024 版权所有
技术支持:北京勤云科技发展有限公司